ENDOTRACHEAL INTUBATION

Introduction

Endotracheal intubation is a lifesaving procedure that requires familiarity with anatomy, physiology, pharmacology, and the necessary equipment required to perform the procedure.

Endotracheal Tube Size Selection

Choice of the correct size of endotracheal tube is fundamental. The average man will accept a cuffed tube with an inner diameter of 8.0 or 8.5 mm. For women, the tube diameter is 0.5 to 1.0 mm smaller. Smaller tubes have more resistance to airflow and may not allow passage of a bronchoscope, but larger tubes may increase injury to the glottis and lower airway.

Equipment and Preparation

It is always best to be fully prepared with the necessary personnel and equipment before attempting endotracheal intubation. If a patient can be adequately oxygenated and ventilated with a bag-valve-mask, emergent intubation is not required. Necessary equipment includes an oxygen source and bag-valve-mask, suction, several sizes of endotracheal tubes and laryngoscopes, and any necessary medications. The light on the laryngoscope and the cuff of the endotracheal tube should always be tested before use.

Laryngoscope Types and Positioning

Familiarity with various laryngoscopes is required. Whereas the curved McIntosh blade is positioned in the vallecula, the space between the base of the tongue and the epiglottis, laryngoscopes with straight blades (Miller) are designed to be placed posterior to the epiglottis. Proper positioning with the patient’s neck flexed and head tilted slightly backward (the “sniffing position”) is essential to provide a straight line from the oral cavity into the trachea.

Laryngoscopy and Tube Insertion

To expose the larynx, the laryngoscope is held with the left hand, and the blade is first placed in the right side and then moved to the middle of the mouth, sweeping the tongue to the left. A straight blade is advanced along the posterior wall of the pharynx, distal to the epiglottis, and then gently lifted and withdrawn against the anterior wall, elevating the epiglottis until the larynx is clearly seen. A curved blade is moved along the base of the tongue until the tip is in the vallecula, and the tongue and epiglottis are lifted forward until the cords are in view. The laryngoscope should not be used to flex or extend the head by wrist movement because this may result in injury to the teeth. Introduction of an endotracheal tube should not be attempted unless the larynx is adequately exposed. A soft-metal stylet may facilitate intubation but should be removed after the tube passes the glottis so as not to injure the trachea.

Nasotracheal Intubation

Nasotracheal intubation is performed in a similar fashion except that the tube is inserted through the larger nostril, and a stylet cannot be used. When the tube reaches the pharynx, it may be grasped with a pair of curved forceps (Magill), with the balloon cuff being carefully avoided, and guided into the larynx and trachea.

Tube Positioning and Confirmation

After the tube has passed the vocal cords, it is advanced to a point approximately 2 to 3 cm proximal to the main carina. The low-pressure cuff is inflated with sufficient air to overcome any leak during forced ventilation. It should be tested intermittently with a gauge to ensure that the cuff pressure does not exceed 20 mm Hg. Adequate placement should be confirmed by auscultation of the lungs and epigastrium, visualization of chest rise, and the use of an end-tidal CO2 detector. After the tube is correctly positioned, it should be adequately secured. It is sound practice to follow intubation with chest radiography to determine the tube’s position.


Medical Editorial Note

This article provides an educational overview of endotracheal intubation, including endotracheal tube selection, airway anatomy, laryngoscopy, tube insertion, and confirmation of tube placement.

Clinical practice update: Contemporary airway management guidance emphasizes the use of continuous waveform capnography to confirm and monitor endotracheal tube placement. Clinical assessment, including chest expansion and auscultation, remains complementary but should not replace capnographic confirmation.

Endotracheal tube cuff pressure is generally recommended to be maintained within approximately 20–30 cm H₂O in adults, measured using an appropriate cuff pressure manometer. The cuff pressure unit and recommended range should be interpreted according to contemporary clinical guidance rather than older references.

Endotracheal intubation is a high-risk procedure that should be performed by appropriately trained healthcare professionals using current institutional protocols and airway management guidelines.

This educational material is not a substitute for professional training, clinical judgment, or emergency medical care.

By pediagenosis

Share with your friends

Give us your opinion

Note: Only a member of this blog may post a comment.

Notification
This is just an example, you can fill it later with your own note.
Done